Connect to the Lincolnshire MeshCore Network
This guide explains how to feed MeshCore data into LincsMesh CoreScope using MQTT and configure regions on a participating repeater
Updated 14 November 2026
This guide explains how to feed MeshCore data into LincsMesh CoreScope using MQTT and configure regions on a participating repeater.
If you are setting up a feeder, follow sections 1–4. If you also operate a repeater, follow section 5 to configure regional traffic.
1. Sign in to LincsMesh
- Open LincsMesh.
- Sign in to your account, or create an account if you do not already have one.
- Open My Account.
2. Register your publishing device
Do this before configuring MQTT. Your publishing device must be linked to your LincsMesh account.
- In My Account, find the companion/node details section.
- Add the MeshCore device you intend to use as your feeder.
- Enter the device’s full public key exactly as shown by your device.
- Set it as your static companion.
- Save your profile and check that the companion is listed.
Use the public key, not a private key. Copy the entire key without extra spaces or missing characters.
For an OpenHop repeater or Gessaman observer: register the publishing device’s public key as your companion, even if the device is already claimed as your repeater. Set this as your static companion.
The public key in your profile must match the device publishing to MQTT. A missing or mismatched key can cause publishing to be rejected even when your MQTT login details are correct.
3. Retrieve your MQTT details
While signed in, open the MQTT / feeder section in My Account. Follow the instructions there to view, request or generate your MQTT credentials.
You will need your LincsMesh MQTT username and password. Your MQTT password is not necessarily the same as your website login password.
Keep these credentials private.
4. Configure your MQTT feeder
Choose the instructions for your setup below.
How do I set up the MQTT feed in Home Assistant?
Before you begin
- Make sure your MeshCore companion is connected to the MeshCore integration in Home Assistant.
- Register its full public key as your static companion on LincsMesh.
- Have your LincsMesh MQTT username and password ready.
Open the MQTT settings
In Home Assistant, go to Settings → Devices & services → MeshCore, then open the integration’s configuration and find MQTT Broker Settings.
Configure the broker
| Setting | Value |
|---|---|
| Enabled | Tick |
| Server | mqtt.lincsmesh.co.uk |
| Port | 443 |
| Transport | websockets |
| Use TLS | Tick |
| Verify TLS Certificate | Tick |
| Keepalive (seconds) | 60 |
| Username | Your LincsMesh MQTT username, e.g. lincsmesh_xxxx |
| Password | Your LincsMesh MQTT password |
| Use MeshCore Auth Token | Leave unticked |
| Token Audience | Leave blank |
| Owner Public Key (JWT owner claim) | Leave blank |
| Owner Email (JWT email claim) | Leave blank |
| Payload Mode | Packet (LetsMesh-compatible) |
| Auth Token TTL (seconds) | Leave at 3600 |
| Status Topic | meshcore/{IATA}/{PUBLIC_KEY}/status |
| Packets Topic | meshcore/{IATA}/{PUBLIC_KEY}/packets |
| Broker IATA Code | Your local airport identifier, e.g. HUY, EMA, DSA, NWI or LBA |
Keep {IATA} and {PUBLIC_KEY} exactly as shown in the topic fields. The integration fills these placeholders automatically.
The JWT owner fields can remain blank when using your LincsMesh MQTT username and password. Your companion’s public key must still be registered in your LincsMesh profile.
Save the settings
Click Submit and complete any remaining configuration prompts.
Check the feed
Visit LincsMesh CoreScope observers and check that your companion is reporting successfully.
How do I set up the MQTT feed for an OpenHop repeater?
Thank you to BlackSpider for writing these instructions.
Before you begin
- Obtain your MQTT username and password from LincsMesh.
- Copy your OpenHop repeater’s full public key.
- Register this key as your companion on LincsMesh, even if the device is already claimed as your repeater.
- Set this as your static companion.
Configure the observer
Log in to the OpenHop web interface and go to System → Observer → Observer config → Edit settings.
| Setting | Value |
|---|---|
| IATA code | Your local airport identifier, e.g. HUY, EMA, DSA, NWI or LBA |
| Status interval | 300 |
| Owner companion key | Your OpenHop repeater’s full public key |
Configure the MQTT broker
Under Broker settings, enter:
| Setting | Value |
|---|---|
| Name | Lincsmesh |
| Format | Meshcoretomqtt |
| Enabled | Tick |
| Transport | Websockets |
| Host | mqtt.lincsmesh.co.uk |
| Username | Your LincsMesh MQTT username, e.g. lincsmesh_xxxx |
| Port | 443 |
| Password | Your LincsMesh MQTT password |
| TLS enabled | Tick |
Save and restart
- Click Done.
- Click Save Settings at the top of the page.
- Click Validate and Restart.
Check the feed
Visit LincsMesh CoreScope observers and check that your repeater is reporting successfully.
How do I set up the MQTT feed using Gessaman observer CLI commands?
Before you begin
- Your device must be running Gessaman’s MQTT Observer firmware.
- Register the observer’s full public key as your static companion in My Account on LincsMesh.
- Have your LincsMesh MQTT username and password ready.
- Make sure the observer’s radio settings match your local mesh.
Custom broker commands can vary between firmware versions. Check the commands supported by your installed build before applying the configuration.
Open the console
Open your observer’s web configuration interface and select CLI, or connect over USB using the console at Gessaman’s observer flasher.
Check your existing configuration
Run:
get mqtt.presets
get mqtt.status
Choose a broker slot you are happy to configure. The example below uses slot 1 and replaces its existing broker settings.
If you use another supported slot, replace mqtt1 with that slot throughout.
Configure Wi-Fi
If your observer is not already connected to Wi-Fi, enter:
set wifi.ssid YOUR_WIFI_NAME
set wifi.pwd YOUR_WIFI_PASSWORD
Replace the placeholders with your own Wi-Fi details.
Configure the LincsMesh broker
The following example uses HUY as the local airport code. Change this if another airport identifier is more appropriate.
Replace YOUR_MQTT_USERNAME and YOUR_MQTT_PASSWORD with the credentials supplied in My Account.
For builds supporting a complete server URL, enter these commands one at a time:
set mqtt1.preset custom
set mqtt1.server wss://mqtt.lincsmesh.co.uk:443
set mqtt1.username YOUR_MQTT_USERNAME
set mqtt1.password YOUR_MQTT_PASSWORD
set mqtt.iata HUY
set mqtt.enabled on
set mqtt.packets on
set mqtt.status on
The wss:// address specifies secure WebSockets.
If your firmware rejects a command or provides separate transport, TLS or port settings, use its version-specific configuration controls with:
| Setting | Value |
|---|---|
| Server | mqtt.lincsmesh.co.uk |
| Port | 443 |
| Transport | WebSockets |
| TLS | Enabled |
| Verify TLS certificate | Enabled |
| Authentication | LincsMesh MQTT username and password |
If a WebSocket path is required, use the value supplied by LincsMesh.
Restart and check
Once all settings have been accepted, restart the observer:
reboot
After it reconnects, check:
get wifi.status
get mqtt.status
get mqtt1.diag
get mqtt.iata
Diagnostic commands may differ between firmware versions.
Confirm that Wi-Fi and MQTT are connected, then visit LincsMesh CoreScope observers and check for your device’s activity.
Your observer’s full public key must match the static companion registered in your LincsMesh profile.
Keep your Wi-Fi and MQTT passwords private when sharing console output or screenshots.
What are the generic MQTT settings?
Use these settings if you are configuring another type of feeder. Your feeder must support MQTT over secure WebSockets.
Before you begin
- Register your publishing device’s full public key as your static companion in My Account on LincsMesh.
- Obtain your LincsMesh MQTT username and password.
Connection settings
| Setting | Value |
|---|---|
| Broker/server | mqtt.lincsmesh.co.uk |
| Port | 443 |
| Transport | WebSockets |
| TLS / SSL | Enabled |
| Verify TLS certificate | Enabled |
| Username | Your LincsMesh MQTT username, e.g. lincsmesh_xxxx |
| Password | Your LincsMesh MQTT password |
| Keepalive | 60 seconds |
| IATA code | Your local airport identifier, e.g. HUY, EMA, DSA, NWI or LBA |
| Payload format | MeshCore packet format compatible with Meshcoretomqtt / LetsMesh |
If your feeder asks for a WebSocket path, use the value supplied by LincsMesh.
MQTT topics
| Message type | Topic template |
|---|---|
| Status | meshcore/{IATA}/{PUBLIC_KEY}/status |
| Packets | meshcore/{IATA}/{PUBLIC_KEY}/packets |
Replace {IATA} with your chosen airport code and {PUBLIC_KEY} with your publishing device’s full public key, unless your feeder fills these placeholders automatically.
The public key must match the static companion registered in your LincsMesh profile.
Save and check
- Enable packet and status publishing where supported.
- Save the settings and restart the feeder if required.
- Check the feeder’s status or logs to confirm it connects successfully.
- Visit LincsMesh CoreScope observers and check for your device’s activity.
Connecting to the broker is only part of the setup. Your feeder must also publish messages using a compatible payload format and the correct topics.
5. Configure regions on your repeater
This section applies to repeaters participating in the Lincolnshire MeshCore Network.
Regions help organise traffic geographically, allowing messages intended for Lincolnshire to travel through participating repeaters while reducing unnecessary propagation into other areas.
MQTT feeding and repeater regions are separate settings. Configuring one does not automatically configure the other.
How do I configure my repeater’s regions?
Connect to your repeater
Connect to your MeshCore repeater using a compatible CLI interface.
Add the regions
Enter the following commands one at a time, pressing Enter after each command. Ensure you receive an ok response before continuing.
region put lincolnshire
region default lincolnshire
region put yorkshire
region put eng-ne
region put northwest
region save
What each command does
| Command | Description |
|---|---|
region put lincolnshire | Adds the Lincolnshire region |
region default lincolnshire | Sets Lincolnshire as the default region |
region put yorkshire | Adds the Yorkshire region |
region put eng-ne | Adds the North East England region |
region put northwest | Adds the North West England region |
region save | Saves the region configuration |
Verify your configuration
Once the regions have been saved, check your configuration using:
region list allowed
Check that the expected regions appear in the allowed list.
Update your repeater information
Update your repeater information on LincsMesh to confirm that your repeater supports the Lincolnshire scope.
This helps others identify repeaters that support Lincolnshire regional traffic.
Configuration notes
- Enter region names exactly as shown, using lowercase letters.
- Run
region saveafter making changes. - Only configure regions appropriate to your repeater and its intended network participation.
- Adding these regions does not itself configure a policy to block unscoped traffic. Existing forwarding and flood settings still apply.
6. Check that your setup is working
MQTT feeder
- Check your feeder’s connection status or logs to confirm it has connected to the MQTT broker.
- Allow time for it to publish status messages and receive MeshCore traffic.
- Open LincsMesh CoreScope observers.
- Find your device and check its latest activity.
Repeater regions
- Run
region list allowed. - Confirm that the expected regions are listed.
- Make sure you have run
region save. - Update your repeater information to show that it supports the Lincolnshire scope.
Troubleshooting
| Problem | What to check |
|---|---|
| MQTT authentication fails | Re-check your MQTT username and password in My Account. Your website password may be different. |
| Publishing is rejected despite correct credentials | Confirm the publishing device is registered as your static companion and its full public key matches your profile. |
| Feeder cannot connect | Check the server address, port 443, WebSockets transport and TLS settings. |
| Feeder connects, but no data appears | Check the topic settings, local airport IATA code and packet publishing settings. Allow time for radio traffic to be received. |
| Only some data appears | Check that both packet and status publishing are configured where supported. |
| You cannot find your MQTT details | Open My Account on LincsMesh and find the MQTT / feeder section. Follow the instructions shown there. |
| A Gessaman CLI command is rejected | Check the commands supported by your installed firmware. Use its web configuration interface if the CLI syntax differs. |
| A Gessaman broker slot stops feeding another service | Check which slot was changed. Configuring a slot replaces its previous broker settings. |
| Expected regions are missing | Check the spelling of each region, add any missing entries and run region save. |
| A region command is not recognised | Check your repeater firmware and consult the CLI documentation for that version. |
If you still need help, contact the LincsMesh site administrator. Include your device or feeder type, software version and any error message.
Never send your MQTT password, Wi-Fi password, token or private key in a public post or screenshot.